Search  

Quad-Z 215 Liquid Handler/Injector

Based on the same robust design as the 215 Liquid Handler/Injector, the Quad-Z 215 features four independent probes with variable horizontal spacing from 9 to 18 mm for access to a wide range of sample vessels.

Features & Benefits
  • Large bed capacity holds up to 17 microplates


  • Accommodates many of Gilson's racks for maximum flexibility for sample transfer between tubes, vials and plates


  • Four independently controlled probesThe 444 QuadDilutor has four independently controlled syringe pumps for use with the four independently controlled probes on the Quad-Z 215 for maximum flexibility across all four channels


  • Optional 849 Multiple-Injection Module enables automated on-line injection onto parallel HPLC systems


  • Optional Vacuum Rack for high-throughput vacuum SPE.Optional Vacuum Rack is ideal for SPE applications






  • Variable probe spacing from 9 mm to 18 mm. Variable probe spacing from 9 mm to 18 mm.
    18mm

 

 

845ZPREP™ System

DOWNLOAD

Quad-Z 215 Liquid Handler/Injector Spec. Sheet
*Automated Fast-Bead Synthesis of Small Peptides (#228)
*Automated Sample Prep/Concentration of Biological Samples Prior to Analysis via MALDI-TOF MS (#222)
*Cost/Benefit Analysis of Automated Pipetting: Fixed Tips vs. Disposable Tips (#208)
*Technical Data for the Quad-Z 215 (fixed probes) Dispensing Small Volumes of DMSO (#200)
444 QuadDilutor User's Guide
Quad-Z 215 Liquid Handler/Injector User's Guide
Vacuum Rack User's Guide
   
Manufacturing Standards Meets applicable safety and EMC certification standards; UL and CE certified
Liquid Handling Reproducibility: 2.1% CV with 1 µL of DMSO

Accuracy
: 104% with 1 µL of DMSO
Injection Volume: 5 µL–5 mL

Reproducibility: 2.0% CV with 500-µL syringe and partial loop filling method; <5.0% CV with 500-µL syringe and total loop filling method

Carryover
:<0.05%
Communication Interface RS-232 or GSIOC; Four inputs (contact closure, TTL, or open-collector), four relay outputs and one switched +24V DC 1A output
Arm Speed X: >45.7 cm/sec (>18 in./sec)
Y: >40.6 cm/sec (>16 in./sec)
Front Panel 8-character display, START and emergency STOP soft keys
Horizontal Motion Strength X: 5 kg (11.1 lbs.)
Y: 7 kg (15.6 lbs.)
Locator Plate Capacity Up to five Code 200-Series racks in the standard locator plate, up to five combined Code 200-series and Code 20/30-Series racks in the standard locator plate, up to seven Code 20- or 30-Series racks in the Code 20- or 30-Series locator plate, or one Code 505 or 505H rack plus one Code 200-Series rack
Power Requirements Frequency: 50–60 Hz
Voltage: 100–120 or 220–240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage
Current rating: 2.5A for 100–120V or 1.4A for 220–240V
Probe Positioning Performance Accuracy:±0.5 mm in X/Y dimensions±1 mm in Z dimension
Repeatability:±0.25 mm in X/Y/Z dimensions
Sampler Type X/Y/Z with stationary rack design
Software Via Gilson TRILUTION™ Software
Syringe Capacity 100, 250 or 500 µL; 1, 5, 10 or 25 mL
Syringe Pump External, integral, high-precision, four-piston (444 QuadDilutor)
Vertical Punch Strength 3.06 kg/probe (6.74 lbs./probe)
Dimensions
(w x d x h)
Quad-Z 215: 91.4 x 61 x 60.8* cm (36 x 24 x 24* in.)
*Maximum height. Z-arm height is adjustable to accommodate vessel heights between 1 and 150 mm (dependent on installed Z-arm).
444 QuadDilutor: 40.4 x 28.7 x 31.2 cm (15.9 x 11.3 x 12.3 in.)
Weight Quad-Z 215: 40 kg (89 lbs.)
444 QuadDilutor: 14 kg (31 lbs.)
† Contact ManSci Customer Service to learn what methods and conditions were used to obtain the values.
 
© 2007 ManSci Inc.