Search  

Multiple Probe 215 Liquid Handler/Injector

Flexible liquid handler and injector is engineered to improve throughput for drug discovery and drug metabolism laboratories. High-throughput capacity is ideal for parallel injection onto HPLC or LC/MS systems.

Features & Benefits
  • Large-capacity, multiple-probe liquid handler processes four or eight samples simultaneously; also performs injection into four or eight parallel systems simultaneously


  • High-throughput automation of basic liquid handling tasks such as: sample transfer, dilutions, mixing, reagent addition and plate reformatting


  • Perfect for high-throughput injection onto FIA/MS, parallel HPLC and MUX systems using the optional 889 Multiple-Injection Module


  • Patented Dual Rail™ syringe drive technology allows for accurate use of one to eight syringes and probes to fit your requirements


  • Ideal for bulk reagent dispensing
845ZPREP™ System
 
DOWNLOAD

Multiple Probe 215 Liquid Handler/
Injector Spec. Sheet
Multiple Probe 215 Liquid Handler/
Injector User's Guide
 
     
Manufacturing Standards
Meets applicable safety and EMC certification standards; UL and CE certified
Arm Speed X: >45.7 cm/sec (>18 in./sec)
Y: >40.6 cm/sec (>16 in./sec)
Communication Interface RS-232 or GSIOC; Four inputs (contact closure, TTL, or open-collector), four relay outputs and one switched +24V DC 1A output
Injection Volume 5 µL–5 mL
Injection Reproducibility <2.0% CV with 500-µL syringe and partial loop filling method; <5.0% CV with 500-µL syringe and total loop filling method
Liquid Handling Reproducibility:0.57% CV with 500 µL of water

Accuracy: 99.2% with 500 µL of water
Front Panel 8-character display, START and emergency STOP soft keys
Horizontal Motion Strength X: 5 kg (11.1 lbs.)
Y: 7 kg (15.6 lbs.)
Injection Carryover† <0.05%
Locator Plate Capacity Up to five Code 200-Series racks or one Code 505 or 505H rack plus one Code 200-Series rack
Maximum Syringe Flow Rates for Water
(with eight syringes installed)
Syringe Size
(µL)
Max. Flow Rate
(mL/min)
100 0.42
250 0.80
500 2.11
1000 4.22
2500 8.40
5000 12.50
Maximum Syringe Flow Rates for Water
(with four syringes installed)
Syringe Size
(µL)
Max. Flow Rate
(mL/min)
100 0.75
250 1.50
500 4.25
1000 8.50
2500 16.75
5000 25.00
Power Requirements Frequency: 50–60 Hz
Voltage: 100–120 and 200–240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage
Current rating: 2.0A for 100–120V or 1.0A for 220–240V
Probe Positioning Performance Accuracy: ±0.5 mm in X/Y dimensions, ±1 mm in Z dimension
Repeatability: ±0.25 mm in X/Y/Z dimensions
Probe Rinse Through a dedicated rinse station for rinsing the inside and outside of the probes
Sampler Type X/Y/Z with stationary rack design
Software Via Gilson UniPoint™ System Software or TRILUTION™ Software
Syringe Capacity 100, 250 or 500 µL; 1, 2.5 or 5 mL
Syringe Pump Integral high-precision, eight-piston syringe pump
Vertical Punch Strength 0.6 kg/probe (1.4 lbs./probe)
Dimensions (w x d x h) 97.8 x 61 x 55.8* cm (38.5 x 24 x 22* in.)
*Maximum height. Z-arm height is adjustable to accommodate vessel heights between 1 and 150 mm (dependent on installed Z-arm).
Weight 39.9 kg (89 lbs.)
† Contact ManSci Customer Service to learn what methods and conditions were used to obtain the values
 
© 2007 ManSci Inc.