Search  

GX-281 Liquid Handler
– for Injection, Fraction Collection and Re-injection

The new GX-281 Liquid Handler features a revolutionary solvent delivery system: there are no syringes to replace or change to accommodate various volumes and flow rates. The Solvent Delivery System features an innovative technology that allows for a large dynamic range of 5 µL to 100 mL and flow rates of 1 µL/min to 25 mL/min.

Features & Benefits
  • Innovative solvent delivery system Revolutionary new Solvent Delivery System with integrated solvent selection of up to 5 solvents: No syringes to replace or change to accommodate different volumes and flow rates; allows for immediate access to up to 5 solvents and provides a large dynamic volume and flow rate range


  • Continuous flow path design on all injection valves for flow rates up to 200 mL/min: Allows system flow to continue even as the injection valve switches from load to inject, ensuring a more consistent pressure and flow


  • New direct-inject injection technologyDirect Injection Module features an injection port that is integrated into the valve: Removes the injection port, a potential source of carryover; reduces rinsing times, sample waste and X/Y travel for quicker injection cycle times


  • Inject, collect fractions and re-inject on the same bed. Enhanced bed capacity over other similar liquid handlers—uses only 35" of linear bench space: Holds up to six Code 200-Series racks with an efficient bed design


  • Separate injection and collection pathways: Ensures that fractions are never contaminated from the injection process


  • New rinse station system includes a high-flow rinse pump: Provides fast and efficient probe cleaning with up to 6 rinse solvents

845ZPREP™ System



DOWNLOAD

GX-281 Liquid Handler User's Guide
   
Manufacturing Standards
Meets applicable safety and EMC certification standards; UL and CE certified
Bed Capacity Twelve 96-well, 384-well
Communication Interface RS-232 or GSIOC; Four inputs (contact closure, TTL, or open-collector), four relay outputs and two switched +24V DC 1A outputs
Liquid Handling Reproducibility: < 2%
Accuracy: + 2% for (1-- uL-25 mL) water
Front Panel Two lines of 40 alphanumeric characters, vacuum fluorescent display
Maximum Flow Rates

Up to 25 mL/min.
(for degassed, HPLC-grade water through the probe)

Power Requirements Frequency: 50–60 Hz
Voltage: 100–120 or 220–240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage
Current rating: 3.5A for 100–120V or 1.75A for 220–240V
Probe Positioning Performance Accuracy: +0.05 mm in X/Y/Z.
Repeatability: + 0.025 mm in X/Y/Z
Probe Rinse Up to six solvents; optional two speed rinse pumps
Sampler Type Cartesian robot featuring integrated pump, HPLC Injectors and Fraction Collection Valve
Software Trilution LC Software
Solvent Delivery Six position bidirectional pump , 2 uL-> 100 mL, Up to 25 mL/min.
Syringe Pump Dual, internal, integral, high-precision
Dimensions
(w x d x h)
88.9 x 76.2 x 96.5 cm (35 x 30x 38 in.)
Weight 68 kg (150 lbs.)
† Contact ManSci Customer Service to learn what methods and conditions were used to obtain the values.
 